Sign In | Join Free | My burrillandco.com
Home > AC Resonant Test System >

Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity

    Buy cheap Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity from wholesalers
     
    Buy cheap Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity from wholesalers
    • Buy cheap Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity from wholesalers

    Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity

    Ask Lasest Price
    Brand Name : Fanke High-voltage
    Model Number : CHX-3000KVA/150KV
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 10sets / 2months
    Delivery Time : 25~35 Working Days
    • Product Details
    • Company Profile

    Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity

    Variable Frequency Resonant Withstand Voltage Test Reactor For Long HV XLPE Cable


    I. Application :


    The high voltage test reactor is HV booster or generator in the variable frequency resonant withstand voltage circuit, it has large capacity and HV for one piece with higher Quality factor putput . it is special for the high voltage XLPE cable test with longer distance .


    Fanke company can finish the design and produce the goods according to all kinds of customer's requirement . such as cylinder type and iron tank type .


    Test reactor can be produced to be 130KV,150KV,155KV,200KV, 250KV, 300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~5A,10A,15A,20A,25A,30A.

    II. Test priciple figure:
    Portable Variable Frequency Resonant Withstand Voltage Test Set

    VF: Variable Frequency Power Supply Source which is control and measurement part in the test circuit.

    T : Excitation Transformer which provide the exciting voltage for HV test reactor
    L : Test Reactor which is resonant inductance in the LC circuit and produce the test voltage

    Cx: Tested Equipment

    MOA1: Lightning Arrestor is protection part on the excitation transformer
    C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm ) which is HV voltage measurement part


    III. General Technical data:

    1. Mode of system test: Series resonant with variable frequency
    2. System model : OEM
    3. Input power supply : 380±10%(three-phase),50Hz/60Hz
    4. Number of HV test reactor: OEM
    5. Rated output capacity: OEM
    6. Rated output Voltage: 150KV or OEM
    7. Max Test voltage : no more than 150KV,300KV,450KV
    8. Rated output current: 25A max or OEM
    9. Reg. Freq range : 20Hz-300Hz
    10. Output Resonance voltage waveform: sine wave
    11. THD of output waveform: ≤1%
    12. Insulation level: Under 1.1 times and keeping 1min, normal
    13. Duty cycle : 60mins on under rated current working condition ;
    14. Quality factor of test set itself: Q≥60
    15. Temperature rise: Less than 65K under rated current working 60mints;
    16. Noise level: No more than 65dB
    17. Reactor Structure: oil immersed type, epoxy tube cylinder type;

    IV.Accessories

    • Necessary corona rings
    • Parallel cables of the reactor
    • HV output cables(reactor to divide)
    • Corona ring for test reactor
    • A final test report, a quality Certificate ,a user manual and a packing list are offered .


    V. Typical model of test reactors


    1 Optional model for 132KV class XLPE cable on-site withstand voltage test


    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-775KVA/155KV155KV5A775KVA132kV cable≤1km
    CHX-1550KVA/155KV155KV10A1550KVA132kV cable≤2km
    CHX-2325KVA/155KV155KV15A2325KVA132kV cable≤3km
    CHX-3100KVA/155KV155KV20A3100KVA132kV cable≤4km
    CHX-3875KVA/155KV155KV25A3875KVA132kV cable≤5km
    CHX-7750KVA/155KV155KV50A7750KVA132kV cable≤10km
    CHX-12400KVA/155KV155KV80A12400KVA132kV cable≤16km
    CHX-15500KVA/155KV155KV100A15500KVA132kV cable≤20km
    Special requirement can be made by order

    Note :Tested cable voltage class≤ 132kV, 0.25uF/km


    2 Optional model for 230KV class XLPE cable on-site withstand voltage test


    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-2020KVA/255KV255KV8A2020KVA220~230kV cable≤1km
    CHX-4080KVA/255KV255KV16A4080KVA220~230kV cable≤2km
    CHX-6120KVA/255KV255KV24A6120KVA220~230kV cable≤3km
    CHX--8160KVA/255KV255KV32A8160KVA220~230kV cable≤4km
    CHX--10200KVA/255KV255KV40A10200KVA220~230kV cable≤5km
    CHX--20400KVA/255KV255KV80A20400KVA220~230kV cable≤10km
    CHX--25500KVA/255KV255KV100A25500KVA220~275kV cable≤12.5km
    Special requirement can be made by order

    Note :Tested cable voltage class≤ 230kV, 0.25uF/km


    3 Optional model for 330KV class XLPE cable on-site withstand voltage test


    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-3500KVA/350KV350KV10A3500KVA330kV cable≤1km
    CHX-7000KVA/350KV350KV20A7000KVA330kV cable≤2km
    CHX-10500KVA/350KV350KV30A10500KVA330kV cable≤3km
    CHX-14000KVA/350KV350KV40A14000KVA330kV cable≤4km
    CHX-21000KVA/350KV350KV60A21000KVA330kV cable≤5km
    CHX-28000KVA/350KV350KV80A28000KVA330kV cable≤10km
    Special requirement can be made by order

    Note :Tested cable voltage class≤ 330kV, 0.25uF/km


    4 Optional other model for long XLPE cable on-site withstand voltage test


    ModelRated voltageRated output currentRated output capacity

    Application

    (From 20Hz starting)

    CHX-2600KVA/130KV130KV10A,20A1300KVAFor U0=64KV and below cable
    CHX-3000KVA/150KV150KV10A, 20A3000KVAFor U0=87KV and below cable
    CHX-10000KVA/250KV250KV20A, 40A10000KVAFor U0=127KV and below cable
    CHX-20000KVA/250KV250KV20A, 80A20000KVAFor U0=127KV and below cable
    CHX-21000KVA/350KV350KV20A, 60A21000KVAFor U0=230KV and below cable
    CHX-42000KVA/350KV350KV20A, 80A42000KVAFor U0=230KV and below cable
    Special requirement can be made by order

    Note : XLPE cable test voltage is considering as 1.7U0


    5 Optional model for HV or EHV class cable and GIS On-site AC hipot test


    ModelRated voltageRated output currentRated output capacity

    Application

    (From 20Hz starting)

    CHX-2600KVA/130KV,260KV130KV,260KV20A@130KV2600KVA

    For U0=64KV cable

    For 72.5KV class GIS

    10A@260KV

    For U0=127KV cable

    For 145KV class GIS

    CHX-9000KVA/150KV,300KV150KV,300KV60A@150KV9000KVA

    For U0=87KV cable

    For 72.5KV class GIS

    30A@300KV

    For U0=160KV cable

    For 170KV class GIS

    CHX-10000KVA/250KV,500KV250KV,500KV40A@250KV10000KVA

    For U0=127KV cable

    For 145KV class GIS

    20A@500KV

    For U0=290KV cable

    For 362KV class GIS

    CHX-20000KVA/250KV,500KV250KV,500KV80A@250KV20000KVA

    For U0=127KV cable

    For 145KV class GIS

    40A@500KV

    For U0=290KV cable

    For 362KV class GIS

    CHX-21000KVA/350KV,700KV350KV,700KV60A@350KV21000KVA

    For U0=190KV cable

    For 170KV class GIS

    30A@700KV

    For U0=290KV cable

    For 550KV class GIS

    Special requirement can be made by order

    VI. On-site test standard table from IEC 60840:2011 and IEC 62067:2011 for XLPE cable



    VII. On-site insulation test standard table from IEC 62271-203:2011 for HV GIS


    Quality Long HV XLPE Cable Testing Device / Hv Test Equipment 3000KVA Or OEM Capacity for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)