Sign In | Join Free | My burrillandco.com
Home > Circuit Breaker Test Set >

Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval

    Buy cheap Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval from wholesalers
     
    Buy cheap Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval from wholesalers
    • Buy cheap Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval from wholesalers
    • Buy cheap Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval from wholesalers
    • Buy cheap Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval from wholesalers
    • Buy cheap Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval from wholesalers

    Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval

    Ask Lasest Price
    Brand Name : Fanke High-Voltage
    Model Number : FKZK
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10units/month
    Delivery Time : 10 work days
    • Product Details
    • Company Profile

    Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval

    Switch Vacuum Inspective Tester , Vacuum Level Analyzer For Vacuum Breaker , Vacuum Level Testing


    I. Products Description and Application


    For checking the insulation degraded level of vacuum circuit breaker , one common test method is by power frequency withstand voltage , however this way just find the defects that the degree of vacuum has been seriously deteriorated. When the vacuum degree has been deteriorated to 10-2----10-1 Pa, although the breakdown voltage did not decrease through power frequency withstand voltage test , the arc extinguishing chamber was still unacceptable.


    The FKZK vacuum switch vacuum level tester uses a new excitation coil and uses the magnetron discharge method to test the vacuum of the arc extinguishing chamber without disassembling the arc extinguishing chamber. At the same time, the microcomputer is used for synchronous control and data acquisition and processing, so that the field test sensitivity in the arc extinguishing chamber can reach 10-5Pa. The most prominent feature of this instrument is the use of a new excitation coil and data processing method to achieve a vacuum measurement without disassembly. The instrument has the advantages of convenient use, simple operation, disassembly measurement and high test accuracy. It is a practical testing instrument and widely used in power, steel, petrochemical, textile, coal, railway and other departments that use vacuum switches.


    II. Test principle of FKZK tester

    Pull open a distance of the two contacts of arc extinguish chamber, apply pulse high voltage, encircle the magnetic coil around the outside on the arc extinguish chamber, connect a large current to the coil, which produces synchronous pulsed magnetic fields in the arc extinguish chamber together with high voltage, so that the electronic in the arc extinguish chamber makes spiral movements due to the pulse magnetic fields and with the collide ionization of residual gas molecules, the resulting ion current is approximately proportional to the residual gas density. For different tubes, in the same vacuum conditions, the ion current size is not the same, when the detect ion current, through an ion current-vacuum curve, the vacuum is automatically calculated by a computer, and the values is displayed.


    II. Features

    1. The apparatus can automatically identify breaker status of on or off for fracture and operates accordingly with clue.
    2. Independent fracture 6 can test and indicate connection status of fracture so that it is convenient for users to check wiring.
    3. The device can store fifty sets of testing results.
    4. Its big screen(320×240)LCD display is an advanced grey screen which does not reflect or black screen in sunshine. Besides, its menu interface with clues of pictures and characters menu operation is rather personal and easy to operate.
    5. The device has powerful graphical analysis function, which makes it possible to display waveform and measured data simultaneously. Thus testing process is more self-evident.
    6. The device contains delay and protection function, which makes it possible to cutoff coil voltage automatically after circuit breaker operates. Therefore, the circuit breaker and the testing instrument are well protected.
    7. The device can be used to carry out electric and manual switch test.
    8. The device can be used in experiment of low voltage and high voltage, and seek the minimum voltage or closing voltage automatically.
    9. It can be used in reclosing experiment for parameters measurement of closing-opening, opening-closing and opening-closing-opening.
    10. Parameter measurement of vacuum contactor (single coil) .

    III. Technical Parameters


    Vacuum measuring range9.999×10-1~1×10-5Humidity≤80% RH
    Ion current measuring range9.999×10-1~1×10-6PowerAC,220V,50 Hz±10%
    Measurement error<10%Dimension420×290×210(mm)
    Resolution10-5 paOutput high voltageImpulse ≤30k V 15k Hz
    Ambient temperature-20℃~50℃Weight8 kg

    IV. Configurations:

    • Magnetron Current Sensor 1 piece
    • Output line of current 2 piece
    • Input line of signal 2 piece
    • Fuse 2 pieces
    • Power line 1 piece
    Quality Automatical Circuit Breaker Test Set Switch Vacuum Interrupter Tester ISO9001 Approval for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)