Sign In | Join Free | My burrillandco.com
Home > AC Resonant Test System >

45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test

    Buy cheap 45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test from wholesalers
     
    Buy cheap 45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test from wholesalers
    • Buy cheap 45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test from wholesalers

    45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test

    Ask Lasest Price
    Brand Name : Fanke High-voltage
    Model Number : CHX-270KVA/45KV,270KV
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10units/2months
    Delivery Time : 25~45 Work Days
    • Product Details
    • Company Profile

    45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test

    Portable Variable Frequency Resonant Withstand Voltage Test Set , For 35KV Cable and 110KV Power Substation Test


    I. Product Usage :

    This test set model CHX-270KVA/45KV, 270KV is designed for 10KV / 35KV class short XLPE cable ,power transformer, CB,CT/PT, busbar in 110KV power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 45KV ,90KV,270KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test


    Test range of the set is as following:transformer

    1. 1000m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 5min.

    2, 3000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.

    3, 35kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 68kV, test time 1min.

    4, 110kV/50000kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 160kV, test time 1min.

    4, CB,CT/PT, busbar in 110KV power substation , test frequency 40-300Hz, test voltage no more than 265, test time 1min.


    The whole test set consists of variable frequency power source , excitation transformer , 6pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV or 110KV power sub-station


    II. General Technical Data


    1. Rated capacity: 270kVA;
    2. Input power: three-phase 380V voltage, frequency is 50Hz;
    3. Rated voltage: 45KV; 270kV;
    4. Rated current: 1A; 6A;
    5. Working frequency: 30-300Hz;
    6. Device output waveform: sine wave
    7. Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
    8. Working time: continuous 60min allowed under rated load; overpressure 1.1 times 1 minute;
    9. Temperature rise: temperature rise ≤65K after continuous operation for 60 minutes under rated load;
    10. Quality factor: device itself Q≥30 (f=45Hz);
    11. Protection function: Over-current, over-voltage and test product flashover protection for the tested product (see the variable frequency power supply section for details);
    12. Measurement accuracy: system effective value 1.5;


    III. Main Components:


    SNName of ComponentsType and specificationQty.Each weightEach Dimension
    1Variable frequency powerFKVF-20kW/380V1piece35kgs480*480*520mm
    2Excitation transformerCQSB(J)-15kVA/2.5KV,10KV1piece130kgs500*500*580mm
    3HV resonant test reactorCHX(kf)-45kVA/45kV6pieces55kgsD420*H480mm
    4Capacitive dividerTRF-270kV/1000pF1set30kgsD200*H2150mm
    5Special test accessories1set

    IV. Test priciple :


    VF: Variable Frequency Power Source T : Excitation Transformer
    L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
    C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


    V. Main Measuring and control software panel:

    Note: This is the software panel before start test for parameter setting



    VI.Accessories

    • Accessory box for storage accessoires
    • Input cables of power source
    • Output cables of power source
    • Output cables of exciting transformer
    • System grounding cables
    • Parallel cables of the reactor
    • HV measuring cables ( the signal output cables of voltage divider )
    • HV output cables(reactor to divide,divider to test object)
    • Insulation supporting base
    • corona ring for 135KV test
    • A final test report, a quality Certificate ,a user manual and a packing list are offered .


    VII. Other Optional Model


    1. For GIS on-site test

    ModelRated voltageRated output currentRated output capacity

    Application

    (From 45Hz starting)

    CHX-135KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-270KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-216KVA/216KV27KV*81A216KVAFor 123KV and below GIS
    CHX-270KVA/270KV27KV*101A270KVAFor 145KV and below GIS
    CHX-275KVA/275KV275KV2A275KVAFor 170KV and below GIS
    Special requirement can be made by order

    2. For 45KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-108/5454KV2A108KVA45kV cable≤1km
    CHX-216/5454KV4A216KVA45kV cable≤2km
    CHX-324/5454KV6A324KVA45kV cable≤3km
    CHX-432/5454KV8A432KVA45kV cable≤4km
    CHX-540/5454KV10A540KVA45kV cable≤5km
    CHX-1080/5454KV20A1080KVA45kV cable≤10km
    Special requirement can be made by order

    3. For 66KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-160/8080KV2A160KVA66kV cable≤0.5km
    CHX-320/8080KV4A320KVA66kV cable≤1km
    CHX-640/8080KV8A640KVA66kV cable≤2km
    CHX-960/8080KV12A960KVA66kV cable≤3km
    CHX-1280/8080KV16A1280KVA66kV cable≤4km
    CHX-1600/8080KV20A1600KVA66kV cable≤5km
    CHX-3200/8080KV40A3200KVA66kV cable≤10km
    CHX-9600/8080KV120A9600KVA66kV cable≤20km
    Special requirement can be made by order

    VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

    Quality 45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)