Sign In | Join Free | My burrillandco.com
Home > VLF High Voltage Testing >

Portable VLF High Voltage Testing Vlf Testing Equipment For Cables 35KV &10KV

    Buy cheap Portable VLF High Voltage Testing Vlf Testing Equipment For Cables 35KV &10KV from wholesalers
     
    Buy cheap Portable VLF High Voltage Testing Vlf Testing Equipment For Cables 35KV &10KV from wholesalers
    • Buy cheap Portable VLF High Voltage Testing Vlf Testing Equipment For Cables 35KV &10KV from wholesalers

    Portable VLF High Voltage Testing Vlf Testing Equipment For Cables 35KV &10KV

    Ask Lasest Price
    Brand Name : Fanke High-voltage
    Model Number : CHX-108KVA/27KV,108KV
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10units/1months
    Delivery Time : 25-30 Work Days
    • Product Details
    • Company Profile

    Portable VLF High Voltage Testing Vlf Testing Equipment For Cables 35KV &10KV

    Portable Variable Resonant Withstand Voltage Test Set , For 35KV &10KV Cable Test , 30~300Hz Test Frequency


    I. Product Usage :


    This test set model FKTF-81KVA/27KV, 54KV is designed for 10KV / 35KV class XLPE cable ,power transformer, CB,CT/PT, busbar in 35KV power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 27KV ,54KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test


    Test range of the set is as following:transformer

    1. 500m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 60min.

    2, 2000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.

    3, 10kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 54kV, test time 1min.

    4, CB,CT/PT, busbar in 35KV power substation , test frequency 40-300Hz, test voltage does not exceed 95kV, test time 1min.


    The whole test set consists of variable frequency power source , excitation transformer , 3pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV power sub-station


    II. General Technical Data


    Application:

    Cross-linked cables with voltage of 10KV,35KV;


    Features:

    The test is with variable frequency resonance way, and the reactor is with cordwood structure.

    Test frequency:30~300HZ or 35~75HZ;

    Output voltage waveform is sine waveform,Waveform deviation factor≤1%;

    Easy connection and operation;

    Small size and light weight of each component is easy for carry and field test;

    It has an intelligent variable frequency power supply, with high automaticity and protective function.

    Cross-linked Cable Voltage Withstand Test System :Length of cable:1~10km (can be ordered);

    Weight of single piece:25kg~50kg;


    III. Main Components:


    SNName of ComponentsType and specificationQty.Each weightEach Dimension
    1Variable frequency powerOEM1piece35kgsOEM
    2Excitation transformerOEM1piece35kgsOEM
    3HV resonant test reactorOEM3pieces42kgsOEM
    4Capacitive dividerOEM1set10kgsOEM
    5Special test accessories1set

    IV. Test priciple :


    VF: Variable Frequency Power Source T : Excitation Transformer
    L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
    C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


    V. Other Optional Model


    1. For GIS on-site test

    ModelRated voltageRated output currentRated output capacity

    Application

    (From 45Hz starting)

    CHX-135KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-270KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-216KVA/216KV27KV*81A216KVAFor 123KV and below GIS
    CHX-270KVA/270KV27KV*101A270KVAFor 145KV and below GIS
    CHX-275KVA/275KV275KV2A275KVAFor 170KV and below GIS
    Special requirement can be made by order

    2. For 45KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-108/5454KV2A108KVA45kV cable≤1km
    CHX-216/5454KV4A216KVA45kV cable≤2km
    CHX-324/5454KV6A324KVA45kV cable≤3km
    CHX-432/5454KV8A432KVA45kV cable≤4km
    CHX-540/5454KV10A540KVA45kV cable≤5km
    CHX-1080/5454KV20A1080KVA45kV cable≤10km
    Special requirement can be made by order

    3. For 66KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-160/8080KV2A160KVA66kV cable≤0.5km
    CHX-320/8080KV4A320KVA66kV cable≤1km
    CHX-640/8080KV8A640KVA66kV cable≤2km
    CHX-960/8080KV12A960KVA66kV cable≤3km
    CHX-1280/8080KV16A1280KVA66kV cable≤4km
    CHX-1600/8080KV20A1600KVA66kV cable≤5km
    CHX-3200/8080KV40A3200KVA66kV cable≤10km
    CHX-9600/8080KV120A9600KVA66kV cable≤20km
    Special requirement can be made by order

    VI. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

    Quality Portable VLF High Voltage Testing Vlf Testing Equipment For Cables 35KV &10KV for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)